Workshop library

HVAC & Thermal

A coolant pump that stopped when hot

Mercedes-Benz W213 (E-Class)

Historical workshop record. The findings below are reported in the original notes; they haven’t been independently re-tested for this publication.

What brought it in

Intercooler low-temperature auxiliary coolant pump randomly shuts off only when the engine reaches full operating temperature.

What the notes record

  1. Intercooler low-temperature auxiliary coolant pump randomly shuts off only when the engine reaches full operating temperature. (W213 Chassis).
  2. Zero fault codes stored. Assumed an intermittent internal pump motor seizure or loose fuse.
  3. Monitored supply voltage at the pump harness connector while heating the engine bay to full operating temperature under load.
  4. Constructed and routed a clean, dedicated fused power feed bypassing the degraded section. Pump operated continuously through high-temperature road testing.

The recorded finding

Internal copper strand degradation inside the wiring harness; wire built excessive resistance only under engine bay heat soak, dropping voltage to the pump. — Constructed and routed a clean, dedicated fused power feed bypassing the degraded section. Pump operated continuously through high-temperature road testing.

Low-Temperature Auxiliary Coolant Pump
Low-Temperature Auxiliary Coolant Pump · Original workshop image
Engine Bay Harness Heat-Soak Trace
Engine Bay Harness Heat-Soak Trace · Original workshop image
Dedicated Fused Bypass Feed
Dedicated Fused Bypass Feed · Original workshop image
Thermal Camera Circulation Verification
Thermal Camera Circulation Verification · Original workshop image

A similar symptom can have a different cause. Bring your own observations and checks into the conversation.